10. OTHER FAILURES
10.1 HYDRAULIC PROBLEMS OF THE COFFEE UNIT
10.1a Doses lighter than initially set
The obtained doses are lighter than initially set

There is a leak located just after the dosing device

The decompression way of the unit
valve leaks during the infusion
process
Check flaps
One of the connections located
after the dosing device outlet leaks
Check waterproofness
Replace gaskets

Repeat dose programing
10.1b Dripping outside infusion periods
Water goes through the unit or the decompression pipe outside
infusion periods

The 3-way valve is opened as a result of the
too highly set expansion pressure
(>13 bar)
The valve flaps
are faulty

Set the high pressure valve opening
at 13 bar
The pump pressure must be set at 10 bar
Check the flaps
Replace the flap
core, as necessary.