EasyManuals Logo

Union Switch & Signal GENISYS II User Manual

Default Icon
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
UNION SWITCH & SIGNAL GENISYS II System Hardware Installation
3-10 August 1999 SM-6900B Rev. 0.0
Note that for ports designated as master ports, this need not be done. The default configuration of
all master ports is point-to-point. Note also that serial port 4 is capable only of point-to-point
operation regardless of its designated function and the value of the POINT.POINT parameter for
port 4.
3.2.8.2 Basic GENISYS Protocol Serial Port Configuration
The standard GENISYS protocol configuration is:
STOPBITS:
1
PARITY:
NONE
CARRIER.MODE:
CONSTANT
SECURE.MODE:
ON
(GENISYS MASTER PORT ONLY)
MASTER.CHECKBACK:
OFF
(GENISYS MASTER PORT ONLY)
CRC.SIZE:
16
Some configuration items are intended to vary with the requirements of the installation. The data
rate (BAUD) should be set to accommodate the requirements of the communication system and
system responsiveness. When interconnection of units is accomplished by direct wire, a data rate
of
19200
BPS should be used to ensure good communication response. When modems are used, a
data rate appropriate for the selected modems should be used. This can be determined by
referring to the application information that accompanies the modem being used.
Key-on (KEY.ON.DELAY) and key-off delays (KEY.OFF.DELAY) should be set to
0
for direct
wire connections. For modem connections, key-on and key-off delays should be set to a value
appropriate for the modems being used. This can be determined by referring to the application
information that accompanies the modem. When simple, frequency-shift modems are used (such
as those manufactured by RFL Industries),
8
- to
12
-bit times is a good value for key-on and key-
off delays. More sophisticated modems and more sophisticated communication links (those with
regenerative repeaters, for example) may require longer key-on and key-off delays. The
approximate required key-on and key-off delays may often be determined empirically by setting
the delays to a high value (about
64
-bit times) and attempting to establish communication. Once
communication is established, the delays can be progressively reduced until communication
becomes erratic. About
4
- to
8
-bit times should be added to the values that produce erratic
operation.
Master port polling timeout (MASTER.TIMEOUT:) must be set to accommodate the worst-case
delay time required for a slave to respond. The default value of
500
milliseconds is usually
adequate. However, when a GENISYS protocol master is communicating with many slaves on a
communication circuit where all slave units may not always be answering, a shorter timeout may
be appropriate to ensure minimum communication delays when slaves occasionally fail to
respond. In any case, the timeout must always be long enough to allow a slave that is capable of
responding sufficient time to respond. This time is approximately equal to twice the worst case
end-to-end delay for the communication channel, plus the worst case communication channel
turnaround delay (relevant only for half-duplex channels), plus the worst case turnaround delay
for a GENISYS II slave port (the time between receiving the last byte of a message and

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Union Switch & Signal GENISYS II and is the answer not in the manual?

Union Switch & Signal GENISYS II Specifications

General IconGeneral
BrandUnion Switch & Signal
ModelGENISYS II
CategoryControl Unit
LanguageEnglish