15
Terminator:
E1
0
Enter (CR/LF)
2 Return(LF)
1 Field Exit(CR) 3 None
Code ID:
E2
0 None
2 Default Set I
1 User Defined 3 Default Set II
Define Code ID:
E3
00
Code 39 Full ASCII 07
Codabar
01
Code 39 Standard 08
Code128
02
EAN-13 09
Code 93
03
UPC-A 10
S 2 of 5
04
EAN-8 11
MSI
05
UPC-E 12
Code 11
06
I 2 of 5 13
Data Length:
E4
0 Exclude
1 Include
PP
Preamble:
Scan “PP” to program
preamble. Scan characters
from Full ASCII table to
define preamble.
Maximum 16 characters.
Scan “PP” to end.
OO
Postamble:
Scan “OO” to program
preamble. Scan characters
from Full ASCII table to
define preamble.
Maximum 16 characters.
Scan “OO” to end.