-67- © 2020 unitech Electronics Co., Ltd. All rights reserved.
unitech is a registered trademark of unitech Electronics Co., Ltd.
MS852B Plus User’s Manual
■ Check for non-numeric character
ED Check to make sure there is a non-numeric ASCII character at the current
cursor position. The format is aborted if the character is numeric.
ED Example: Only output the data if the bar code begins with a letter
If you want only data from bar codes that begin with a letter, you can use
ED to check for the letter.
Command string: EDF10D
ED is the “Check for a non-numeric character” command
F1 is the “Send all characters” command
0D is the hex value for a CR
If this bar code is read , the next data format, if there is one, will be
used on the data. If there is no other format, the format fails and the raw data is
output as AB1234. If this bar code is read: the data is output as:
AB1234