2.32.7 Data Format Non-Match Error Tone
When a bar code is encountered that doesn’t match your required data format,
the scan engine normally generates an error tone. However, you may want to
continue scanning bar codes without hearing the error tone. If you scan the
Data Format Non-Match Error Tone Off bar code, data that doesn’t conform to
your data format is not transmitted, and no error tone will sound. If you wish to
hear the error tone when a non-matching bar code is found, scan the Data
Format Non-Match Error Tone On bar code. Default = Data Format Non-Match
Error Tone On.
Data Format Non-Match Error Tone On *
Data Format Non-Match Error Tone Off
Data Formatter On, Not Required, Keep Prefix/Suffix *
Data Format Required, Keep Prefix/Suffix
Data Formatter On, Not Required, Drop Prefix/Suffix
Data Format Required, Drop Prefix/Suffix