If the laser machine was improperly shut down, the engraving table will home at start up. To have this •
feature turned o, check the ‘Disable Automatic Z-Homing. Disabling this feature can also be helpful when
troubleshooting Z-Axis problems.
If you would like the laser system to re-home before it engraves a job, select ‘Home XY Before Engraving.•
Universal laser systems contains an Air Pressure detection switch. This feature is only present when you use Manual •
Air Assist. To enable this feature, check the DETECT AIR PRESSURE box. If sucient air pressure (1.5 psi) is not
present, then an error message is displayed. If you use Computer Controlled Air Assist, this feature is not present
because our laser system automatically detects if sucient air pressure is present.