LPX SEED TREATER
ELECTRICAL PANEL
Check and tighten wire connections.
Check quick connects on bottom of control panel.
Check to see if starters and/or overloads are tripped.
Check to see if relays, timers and/or breakers are tripped.
Check and set the proximity switches (page 53).
Check quick connects on end of Auxiliary cord.
Check and tighten wire connections.
Check relay and fuse holder.
Check power cords for cuts or frays and ensure ground is present.
MIX TANK
Check motor.
Check motor for any play in the mix tank shaft.
Check valves, fittings, and plug on bottom of tank for leaks.
Check chemical line tubing for abnormal wear.
Wipe down the motor casing with a damp cloth making sure to remove all dust that
may have collected since the last maintenance date. Record the cleaning on the
company required documents. If operating in a CSA 22.1, Class II, Division 2,
Group G hazardous area, USC recommends this step be performed on a daily
basis.
Essuyez le carter moteur avec un chiffon humide en veillant à éliminer toutes les
poussières qui peuvent avoir perçu depuis la dernière date de maintenance.
Enregistrez le nettoyage sur la société les documents requis. Si opérant dans un
CSA 22.1, Classe II, Division 2, Groupe G zone dangereuse, USC recommande
cette étape être effectuée sur une base quotidienne.