Floor Screed Machine HD 50 7
www.utiform.com departamento.técnico@utiform.com Tfno. + 34 96 570 29 82 Fax: + 34 96 570 29 83
2.8 Cleaning the machine.
It is important to keep the machine free of encrusted dirt, and therefore biological machine conservation
liquid should be used to protect from corrosion and separation.
Under no circumstances should you use diesel fuel for cleaning and care of the machine, since it may
cause irreparable damage, above all to plastic seals and parts.
Use and remove the substances and materials used, in particular:
• in any work carried out in lubrication systems and devices and
• in cleaning with solvents.
2.9 Safety regulations for towed machines
General safety indications
1. The person who activates the machine is responsible for keeping it in a state of safe operation.
2. Use only oils and grease and lubricants recommended and authorized by UTIFORM. Bear in mind that
the lubricants chosen should comply with all safety regulations particularly in respect of fire hazard, due
to oil or explosions and the possibility of formation or transformation of dangerous gases.
3. The person responsible for the machine should ensure due compliance with all regulations with respect to
the handling, maintenance of the machines and tools.
4. Maintenance, servicing and repair work should only be carried out by qualified personnel if necessary
under the guidance of a person specially trained in this work.
5. If there is any suspicion or indication that a part in the machine interior has overheated, the machine
should be disconnected. Under no circumstances should you open the control caps before the machine has
cooled down sufficiently, in order to avoid the machine catching fire when the oil vapors mix with
oxygen.
6. All maintenance work should be carried out when the machine is stopped.
7. Prior to dismantling any pressurized part, disconnect the compressor or all the equipment pressure
sources and release pressure from the whole system. In addition, all valves should have a sign stating
“work in progress" on the machine "do not open.”
8. Prior to starting repair work, ensure that the installation cannot be connected either through
carelessness or accident. As a further safety measure, place a warning notice on the starter device
stating “Machine repair in progress, do not connect”.
In installations using diesel, the battery should be dismantled or insulating covers should be placed over
the clamps
If the installation is electric, the main switch should be off and all the safety devices should be
deactivated. Place a warning sign on the short circuit box or the main switch stating “Machine repair in
progress, do not connect”.
9. Limit values (pressure, temperature, revolution adjustment etc. ) should be clearly marked.
10 Never activate machines or tools which are either over or under their limit values (pressure,
temperature, number of revolutions, etc.)
11 Keep an operation log, noting operation data and maintenance work carried out.
12. The HD-50/07should be kept clean at all times, that is, free from oil and other residue and dust.