PUMP TO HOUSE CONNECTION (DISCHARGE PIPE)
3. Wrap thread tape around the threads of a
1 in. discharge tee (not included). Using a
pipe wrench, thread the 1 in. discharge tee
into the 1 in. opening in the top of the tank
tee.
4. Install a 1 in. MPT x 1/4 in. FPT galvanized
bushing and (optional) pressure gauge (both
not included), or a pipe plug (not included). Do
not tighten, as you will prime pump/tank (A)
later at this location.
5. Wrap thread tape around the threads of a 1 in.
male PVC adapter (not included) and thread
the adapter into the discharge tee.
1 in.
Discharge Tee
1 in. male
PVC adapter
5
Pressure Gauge
or Pipe Plug with
Bushing
1 in.
Discharge Tee
4
1 in.
Discharge Tee
Tank Tee
3
2
Tank
Inlet
2. Wrap thread tape around the tank inlet
threads on pump/tank (A). Insert tank hose
gasket (AA) into the inlet of tank hose (B).
Using wrench, tighten tank hose (B) onto tank
inlet.
A
B
AA