EasyManua.ls Logo

Utilitech 0752650 - User Manual

Utilitech 0752650
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Español p. 31
Français p. 16
Serial Number
Purchase Da
te
ATTACH YOUR RECEIPT HERE
Lowes.com
Questions, problems, missing par
ts? Before returning to your retailer, call our
customer service department 1-866-994-4148, 8 a.m. - 8 p.m., EST, Monday - Friday.
1
Utilitech & UT
Design
®
are registered
trademarks of LF
, LLC. All rights reserved.
AB15905
ITEM #0752650
1HP
CONVERTIBLE
JET PUMP
MODEL
#EFCWJ10-L
®

Questions and Answers

Overview

This document is a user manual for the Utilitech 1HP Convertible Jet Pump, Model #EFCWJ10-L, Item #0752650. It provides detailed instructions for assembly, installation, operation, troubleshooting, and maintenance, along with safety information and a parts list.

Function Description:

The Utilitech 1HP Convertible Jet Pump is designed for pumping water in both shallow and deep well applications. It is a versatile pump that can be configured for different well depths, making it suitable for a range of residential water systems. The pump is capable of drawing water from wells and delivering it to a household plumbing system, often in conjunction with a pressure tank. It is specifically designed for water systems and is not intended for pumping chemicals, corrosive liquids, gasoline, or other flammable liquids.

Important Technical Specifications:

  • Power: 1 HP (Horsepower)
  • Model Number: EFCWJ10-L
  • Item Number: 0752650
  • Voltage: Designed to run on either 115 Volt or 230 Volt current, with a conversion switch provided for selection.
  • Pressure Switch: Equipped with a 30/50 PSI pressure switch. The tank air pressure must be set at 28 PSI (2 PSI lower than the "cut-in" pressure of the switch) when there is no water in the tank.
  • Wiring: Requires a separately fused, grounded line with a minimum capacity of 15 amps. A non-fused breaker at recommended amperes can also be used. Specific wire sizes (copper) and fuse sizes (amps) are provided in a chart based on the distance from the motor to the meter for both 115V and 230V single-phase motors. For example:
    • 0-50 Ft.: 12 AWG (115V), 14 AWG (230V); Fuse Size: 30 Amps (115V), 15 Amps (230V)
    • 50-100 Ft.: 12 AWG (115V), 14 AWG (230V); Fuse Size: 30 Amps (115V), 15 Amps (230V)
    • 100-150 Ft.: 10 AWG (115V), 12 AWG (230V); Fuse Size: 30 Amps (115V), 15 Amps (230V)
    • 150-200 Ft.: 8 AWG (115V), 12 AWG (230V); Fuse Size: 30 Amps (115V), 15 Amps (230V)
    • 200-300 Ft.: 6 AWG (115V), 10 AWG (230V); Fuse Size: 30 Amps (115V), 15 Amps (230V)
  • Well Depth (Lift):
    • Shallow wells: 0-25 ft. lift (ejector bolts to pump). Suction lift should be less than 25 ft.
    • Deep wells: 0-70 ft. lift (ejector installed in the well, well inside diameter 4 in. or more). Suction lift should be less than 90 ft.
  • Internal Treatment: Areas inside the pump housing are treated with a non-toxic, vegetable-based rust inhibitor.

Usage Features:

  • Convertible Design: Adaptable for both shallow and deep well applications by adjusting the ejector installation.
  • Priming: Detailed instructions are provided for priming the pump, which involves filling the suction pipe and pump with water until overflow, then running the pump and repeating if water is not produced within 30 seconds.
  • Installation Flexibility: The manual provides comprehensive instructions for installing the pump in both shallow and deep well configurations, including specific pipe sizes, adapters, and fittings required (not included with the pump).
  • Pressure Regulation (Deep Well): For deep well applications, a pressure regulator kit is used, and a flow control (not included) is recommended to improve performance and consistency, regulate water pressure fluctuations, and prevent loss of prime.
  • Safety Precautions: Emphasizes disconnecting power before any work, proper grounding, avoiding extension cords, and protecting the power cable from damage.
  • Motor Switch Settings: Users must ensure the motor's wires are correctly attached to the control panel for the selected voltage (115V or 230V).

Maintenance Features:

  • Draining for Freezing Protection: Instructions are provided to drain the entire system, including removing the drain plug and priming plug, if there is a danger of freezing.
  • Troubleshooting Guide: A comprehensive troubleshooting section helps diagnose common issues such as little or no discharge, failure to deliver water or develop pressure, excessive noise/vibration, and failure to start/run. It lists possible causes (e.g., pump not primed, air leak, foreign material, incorrect voltage switch, blown fuse) and corresponding corrective actions (e.g., follow priming instructions, repair/replace parts, tighten connections, clean pump).
  • Non-Repairable Internal Parts: The motor housing should not be disassembled as the pump has no repairable internal parts, and disassembly may lead to leakage or dangerous electrical issues.
  • Warranty: A limited warranty covers defects in material and workmanship for one year, with obligations limited to repairing or replacing defective parts. The warranty excludes incidental damages, transit damage, misuse, accident, or negligence.

Parts List (Replacement Parts):

The manual includes a list of replacement parts with their descriptions and part numbers:

  1. Ejector Kit: 091CJET01
  2. Volute: 091CJET02
  3. O-ring 1: 091CJET03
  4. O-ring 2: 091CJET04
  5. Pressure Switch: 091CJET05

Utilitech 0752650 Specifications

General IconGeneral
BrandUtilitech
Model0752650
CategoryWater Pump
LanguageEnglish

Related product manuals