EasyManuals Logo

Utilitech 0955552 User Manual

Utilitech 0955552
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
15
5. Once pump/tank (A) is lled, wrap the
pressure gauge or discharge tee plug, and
vent plug threads with thread tape, and
thread into pump/tank (A). Tighten with
wrench.
NOTE: Before turning on breaker, open several
outlets or faucets to allow water ow during
priming.
6. Turn on breaker to start pump/tank (A).
IMPORTANT: If pump/tank (A) hums
instead of pumping or turns off repeatedly, shut
pump off immediately. Check voltage. Make
sure your incoming voltage matches pump/tank
(A) wiring voltage. See PUMP ELECTRICAL
CONNECTIONS.
IMPORTANT: If pump/tank (A) fails to prime
within ve minutes:
Turn power off at the breaker box and check all
pipe connections for leaks. All connections must
be water and air tight in order for
pump/tank
(A)
to operate.
1 in. Discharge Pipe
Discharge to
Home
1-1/4 in.
Suction
Pipe
Foot Valve
Well
20
20
Breaker Box
Vent Plug
Pressure
Gauge or
Pipe Plug
5
6
7
7. Check suction pipe for any sagging. Support
suction pipe in a straight line to
pump/tank
(A).
NOTE: Look for leaks or a milky color in the
discharged water, which indicates an air leak.
Re-prime if necessary, following steps 1 through
6 above. Reset breaker at the breaker box. All
connections must be water and air tight in order for
pump/tank
(A) to operate.
A