6
1. Thread 1-1/4 in. male PVC adapter (not
included) into a 1-1/4 in. foot valve (not
included). Hand tighten, then tighten 1/2 turn
with a pipe wrench.
CAUTION: Dry-t entire assembly to ensure proper t before gluing or taping parts.
CAUTION: Follow all proper gluing procedures as specied by the glue manufacturer. Always
glue in a vertical direction whenever possible to prevent glue from dripping inside pipe or ttings
CAUTION: Use pipe tape and pipe paste compound on all male threads. Tighten with wrench to
a snug t and add another 1/4 turn to ensure proper seal.
2. Using a 2-step PVC system (not included),
attach enough 1-1/4 in. PVC pipe and
couplings (not included) to the adapter to
equal the depth of the well, minus 5 ft.
WELL TO PUMP CONNECTION (SUCTION PIPE)
1-1/4 in. male
PVC adapter
1-1/4 in. Foot valve
1-1/4 in. PVC pipe