Tire gauge
Tank
Air Valve/Stem
6
IL1369
Glue
To House
Plumbing
From Pump
Shut off valve
Reducer
Bushing
5
Glue
Tee
Union
1 in. pipe
4
5. Attach the pipe from the pump to the tee
installed in Step 4. Then, from the tee,
install 3/4 in. pipe and optional shut off
valve (not included) to connect tee to
house plumbing.
6. IMPORTANT: Air pressure in the tank
must be 2 PSI lower than the “cut-in”
of the pressure switch. Pump (A) has
a 20/40 PSI pressure switch, so tank
pressure must be set at 18 PSI. Locate
the air valve/stem on the tank and check
pressure with a tire gauge (not included).
If air needs to be removed, press down on
valve to bleed off air. Use a tire pump or
air compressor to add air if needed.
4. Attach a 3/4 in. pipe (not included) to the
reducer bushing. Install an optional 3/4
in. union (not included) and continue with
pipe and 3/4 in. x 3/4 in. x 3/4 in. tee (not