EasyManua.ls Logo

Uwatec Smart 2 - SmartTRAK Software Features

Uwatec Smart 2
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
II System and operation
UWATEC
®
Smart dive computers
2.2 SmartTRAK
With SmartTRAK you can transfer dive data to a personal computer and graphically display the data.
The following settings may be changed with SmartTRAK:
Unit system metric/imperial
Audible attention signal suppression selective
Gauge mode on / off
Depth alarm 5 - 100 m (20 - 330 feet)
Backlight illumination duration 2-12 sec.
Maximum partial pressure of oxygen (ppO
2 max
) 1-1.95 bar
Time limit to reset the O
2
% mix to air no reset / 1 - 48 hrs.
Minimum reserve pressure at the end
of the dive (basis for RBT calculation) 20 120 bar (300 - 1750 psi)
Tank pressure alarm 50 - 200 bar (750 - 2900 psi)
Workload sensitivity 25 steps
The following data may be recalled with SmartTRAK:
Number of past dives
Total duration of past dives
Atmospheric pressure
Pairing information
Dive profile
Logbook
Temperature curve
Workload curve
Alarms and attention messages
II
English

Table of Contents

Related product manuals