9
II System and operation
UWATEC
®
Smart dive computers
2.2 SmartTRAK
With SmartTRAK you can transfer dive data to a personal computer and graphically display the data.
The following settings may be changed with SmartTRAK:
Unit system metric/imperial
Audible attention signal suppression selective
Gauge mode on / off
Depth alarm 5 - 100 m (20 - 330 feet)
Backlight illumination duration 2-12 sec.
Maximum partial pressure of oxygen (ppO
2 max
) 1-1.95 bar
Time limit to reset the O
2
% mix to air no reset / 1 - 48 hrs.
Minimum reserve pressure at the end
of the dive (basis for RBT calculation) 20 120 bar (300 - 1750 psi)
Tank pressure alarm 50 - 200 bar (750 - 2900 psi)
Workload sensitivity 25 steps
The following data may be recalled with SmartTRAK:
Number of past dives
Total duration of past dives
Atmospheric pressure
Pairing information
Dive profile
Logbook
Temperature curve
Workload curve
Alarms and attention messages