-Weight unit is changed
NOTE:
When scale is not at a zero weight status, MC will not
function. Remove all loads off the platter and try again
5.9 LOW BATTERY
The low battery sign appears when input voltage is below
the lowest input limit. Please recharge the scale
immediately. Failure to do so may cause unrecoverable
damage to the rechargeable battery.
5.9.1 In the case of a Rechargeable Battery being used
The indicator will be power off in about 5 to 10 minutes.
Recharge the battery now.
5.9.2 In case of a Power Adaptor being used
Check power supply to indicator immediately.
NOTE:
If LO BAT status is detected during power on, indicator
shows P_OFF and the indicator will be powered off
automatically.
6. TROUBLE SHOOTING
Symptom Indicator cannot be turned on
Check: Is the indicator powered properly?
Action: Check power supply to indicator.
Symptom Indicator turned off automatically
Check Is Auto Power Off Function employed?
Action Refer to 4.2.2 to disable Auto Power Off
Function.
Check Is the LO-BAT INDICATOR on?
Action Check power supply.
Symptom Rated capacity cannot be reached
Check Is the NET INDICATOR on?
Action: Turn the indicator off. Remove all loads
and turn on again.
Check Is there anything obstructing the scale?
Action Remove all obstacles.
Symptom Blank display with only "kg" or "lb"
Check Is the load applied to scale excess the rated
capacity?
Action Remove all loads and try again.