2 EASY
CONFIGURATIONS
Debug State
6.Waiting Timing:
Select item 6 to enter
Waiting Timing
setting
page.The setting range is from 006~600s.
Set 2 digit
number calling
* Cancel # Save
(0~1)
[ - ]
5. Doorplate Mode [0]
* Cancel # Save
[ : : : : : : : : ]
5. Doorplate Mode [11]
Input 0
0: *
1: 123
2: ABC
3: -
* Cancel # Save
[ * * * * * *1 1 ]
5. Doorplate Mode [11]
0: *
1: 123
2: ABC
3: -
* Cancel # Save
(006~600)
[ - - - ]
6.Waiting Timing [040]
7.Talking Timing:
Select item 7 to enter
Talking Timing
setting page.
The setting range is from 006~600s.
8.Installer Code:
Select item 8 to enter
Installer Code
setting page.
(Setting 8 digit numbers).
9.Default:
Select item 9 to enter
Default
setting page. Input the setup
code to restore factory setting.
* Cancel # Save
(006~600)
[ - - - ]
7. Talking Timing [090]
* Cancel # Save
(********)
[ - - - - - - - - ]
8. Installer Code ...
* Cancel # Save
Please input password
[ - - - - - - - - ]
9. Default ...
During working at debug
state,press "1#" to enter
tools page.
Press NO.“2” to enter
Setup item.
Setup page overview.
1.Language:
Select item 1 to enter
Language
setting page. Select
the language you need.(Refer to the following
UI Update
section).
2.Tone Select:
Select item 2 to enter
Tone Select
setting page. Select
the Tone you want. (Refer to the following
Tone Update
section).
Descriptions:
SETUP
Pres NO.
to select
*Back
Tools
Press No.
to select
*Back
Setup
1.Installer Setup
2.Setup
3.Card Manage
4.Online Monitors
5.Online Devices
6.Voltage Measure
1. Language [0]
2. Tone Select [01]
3. Tone Volume [3]
4. Unlock Code [1111]
5. Work Mode [0]
6. Clock ...
7. Setup Code ...
8. About ...
9. Default ...
0-# Redial
1-# Tools
2-# Exits
* Cancel # Save
1. Language [0]
00 English
* Cancel # Save
2. Tone Select [01]
00 Mute
01 Tune
02 English
3.Tone Volume:
Select item 3 to enter
Tone Volume
setting page.
The setting range is 0 ~ 9.
* Cancel # Save
(0~9)
[ - ]
3. Tone Volume [3]
DMR18S Technical Menu -5-