Basic Tools Detail:
Item Description
Factory
set
IDCode
Ifonlyonedoorstationisinstalledinthisbuilding,set
to0;
Ifmultidoorstationsareinstalled,primarydoorstation
mustbesetto0,andotherslavedoorstationsmust
besetfrom1to3.Notethatmax.4doorstationsare
availableinonebuilding
[0]
Single
UnlockTiming
Tosetthetimethathowlongthedoorkeepsopen
whendoorisreleased.Rangefrom01to99seconds.
[01]
1seconds
UnlockOutput
Tosettheunlockmodetomatchthecorresponding
lock.Rangefrom0to1.
0:Power-on-to-UnlockMode(NormallyOpenMode)
1:Power-off-to-UnlockMode(NormallyClosedMode)
0
MonitorTiming Toshowthemonitortime,Rangefrom6sto600s 600s
DoorplateMode
Tosetthecallingmode.Ifsetto0,it'stheauto
mode,thatmeansthecallingwillbeactivateddirectly
afterinputting2digitscode.Ifsetto1,it'sthemanual
mode,thatmeansyoushouldpress"#"buttonto
activatethecallingafterinputtingthecode.
[0]
Automode
WaitingTiming Toshowthecallingwaittime,Rangefrom6sto600s 40s
TalkingTiming
Toshowthelimitationtimeoftalking,Rangefrom6sto
600s
90s
InstallerCode... Tochangedoorstationadministratorcode [66666666]
Default...
Notethisoperationisirreversible.Oncerestoreis
activated,allparameterswillreturntofactorydefault
settingexcepttheinformationofaccesscard.
Table2(InstallerSetup):