ENGLISH
D
ISPLAY
D
ATA
D
ESCRIPTION
DEFAULT
SCor
DEFAULT
AntE
MEMO
DATA
St.rt Operation modes StAn StAn
no - Start inputs from terminal board are disabled
StAn - Standard operation
AP.CH - Separated opening and closing commands
PrES - Manned operation
oroL - Timer operation
StoP STOP input no no
no - STOP input not available
invE - STOP command stops the gate: START command starts
moving in the opposite direction
ProS - STOP command stops the gate: pressing the START command
gate continues the motion
Fot 1 PHOTO 1 input APCH no
APCh - Input is available for the connection of the photocell
no - Not available
Fot 2 PHOTO 2 input CFCh CFCh
CFCh - Photocell is active in closing and also when the gate is still
no - Not available
Ch - Photocell is active during the closing
tESt Test of safety devices no no
no - Function not active
Foto - Test enabled only for photocells
CoSt - Test enabled only for safety edges
Ft.Co - Test enabled either for photocells or for safety edges
ShAd Photocell 2 shadow zone no no
no - Function disabled
F.ShA - FOTO2 disabling higher time
i.ShA - FOTO2 disabling lower time
CoS1 no/Si Border 1 input (fixed border) no no
CoS2 no/Si Border 2 input (mobile border) no no
FC.En no/Si End of stroke inputs (CITY1 only) Si no
FC.En Limit switch / Encoder input (only CITY1-ECD) no no
no - Inputs disabled (the controller ignores them)
EnCo - Inputs enabled as encoders
FC - Inputs enabled as limit switches
riLA Si/no Motor Release on Mechanical Stop Si Si
t.inA 0 ÷ 8 Max. gate quiescent time 0 0
ASM 0.5” ÷ 3.0” Anti-skid 0.5” 0.5”
no - Function disabled
SEnS 0 ÷ 10 Obstacle sensor level 5 5
Cont Counter viewing tot tot
tot. - Total number of completed cycles (views in thousands or in units)
Man - Number of cycles before the next request for service (such a number
has been rounded off to hundreds and it can be set up on 1000-step;
in case it is set up on 0, the request will be disabled and no will be viewed)
APPr Automatic learning of the operation time no no
no - Function disabled
Go - Start up of the automatic learning procedure
FinE End of programming no no
no - It does not exit from the program menu
Si - It exits from the program menu by storing the setup parameters
CITY1 FUNCTION TABLE