Loading...
ENGLISH
47
CONNECTION
SUITABLE CABLE
[N° WIRES PER SECTION]
SUITABLE CABLE GLAND
N
ETWORK
3
x 1.5 mm
2
P
G9: For cables with external Ø from 5 to 8 mm
ACTUATOR 4 x 1 mm
2
PG9: For cables with external Ø from 5 to 8 mm
EXTERNAL ANTENNA SCREENED RG58 PG9: For cables with external Ø from 5 to 8 mm
FLASHING LIGHT 2 x 1.5 mm
2
PG9: For cables with external Ø from 5 to 8 mm
ELECTRO LOCK 2 x 1.5 mm
2
PG9: For cables with external Ø from 5 to 8 mm
OTHER WIRINGS
MULTIPOLAR
n x 0.25 - 0.5 mm
2
(n) depending on the number of
wirings to be made
PG9: For cables with external Ø from 5 to 8 mm
PG11: For cables with external Ø from 7 to 10.5 mm
PG13.5: For cables with external Ø from 9 to 12.5 mm
C
ABLES TABLE
For the wiring to the control unit refer to the following table:
WARNING: To assemble a PG cable gland higher than 9 it is necessary to enlarge the pierce on the plastic shell. Instead of the cable
gland, it is possible to use flexible pipes with IP55 connection.