TERMINAL CONNECTION
1. Antenna
2. Antenna shield.
3.
Opening control for the connection of
control devices with N.O. contact,
TTNC, VRD
4.
Opening controls for pedestrian
access for the connection of control
devices with N.O. contact, TTNC, VRD
5. Stop command. N.C. contact
6. Common (-)
7. Photocell 1.
N.C. contact
8. Photocell 2. N.C. contact
9. Common (-)
10.-11.
Power output 24 VAC for
photocells and other accessories
11.-12.
Photocell TX power supply for
functional tests
WARNING: we suggest to use the external aerial (model ANS433
or ANSGP433) in order to guarantee the maximal range.
PD5
only
13.-14. Electric lock 12 VAC
14.-15. Warning light 24 VAC - 3W
16.-17. Courtesy light 230V / 120V - 10A
18.-19. Flashing light 230V / 120V - 40W
20.
Power output 230V / 120V for motor
2 in opening phase
21. Common motor 2
22.
Power output 230V / 120V for motor 2
in closing phase
23.
Power output 230V / 120V for motor 1
in opening phase
24. Common motor 1
25.
Power output 230V / 120V for motor 1
in closing phase
26. Neutral 230V / 120V
27. Power phase 230V / 120V