ENGLISH
BACKLASH TIME
To avoid that the gate starts the opening phase
before the electrical locks is unhooked, it is possible
to introduce a time of inversion adjustable from 0 to
120 seconds (± 0,5). In this way during the opening
phase, the gate inverts the motion through the set
time permitting the unhooking of the electrical lock.
PRE-FLASHING TIME
This menu permits the introduction of a pre-flashing
that occurs before any movement of the gate either
in opening or in closing phase: the time of
pre-flashing can be adjusted from 0 to 120 seconds
0,5).
SLOWING DOWN TIME (Pd5 only)
This menu permits the activation of the gate slowing
down function for a time to be set between 0 and
120 s(± 1,5 s). To set the slowing down function
proceed as follows: leave a slowing down time at 0
and make sure that the gate opens and closes
correctly. After that, set the slowing down time (for
ex. 5 or 6 s).
FAST CLOSING TIME AFTER SLOWING DOWN
DURING CLOSING (Pd5 only)
When a slowing down time different from 0 s is set,
it is possible that the gate speed is not sufficient to
tr
igger the loc
k dur
ing closing.
For this reason, after
the end of the slowing down phase, it is possible to
close the gate at a normal speed (without slowing
down) for a time to be set between 0 and 120 s
0,5).