PREPARATORY STEPS
The new series of actuadors VULCAN, has been devised to serve
gates up to 800 Kg with leaf up to 3 meters wide (look at the
table technical data). Before proceeding with the installation,
please make sure that your gate opens and closes freely, and that:
Hinges and pins are in optimum condition and properly
greased.
No obstacles are within the moving area.
There is no friction with the ground or between the leaves.
The stop limit switch must be installed inside the foundation
box (see paragraph about Installation of the stop limit switches)
INSTALLATION LAYOUT
1 1
2
4
3
C
5
D
A
B
LENGTH OF THE CABLE < 10 metres from 10 to 20 metres from 20 to 30 metres
Power supply 230V 3G x 1,5 mm
2
3G x 1,5 mm
2
3G x 2,5 mm
2
Photocells (TX) 2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
Key switch 4 x 0,5 mm
2
4 x 0,5 mm
2
4 x 0,5 mm
2
Photocells (RX) 2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
Flashing light 2 x 1,5 mm
2
2 x 1,5 mm
2
2 x 1,5 mm
2
Antenna (integrated into the flashing light) RG174 RG174 RG174
A
B
C
D
1
2
3
4
5
Key switch
Pillar photocells
Pillar-mounted digital radio switch
Safety edges
Motor
Transmitter
Control unit
Photocells
Flashing light
COMPONENTS ADDITIONAL ACCESSORIES