= Parameter value can be changed only when the frequency converter is stopped. (Continues)
Code Parameter Range Step Default C
u
s
t
o
m
Description Page
3.1
Analogue output func-
tion
014 1 1
0 = Not used
1 = O/P frequency
2 = Motor speed
3 = O/P current
4 = Motor torque
5 = Motor power
6 = Motor voltage
7 = DC-link volt.
8 = Input signal U
in
9 = Input signal I
in
10 = Refer. freq.
11 = Refer. torque
12 = Motor±torque
13 = Motor±power
14 = O/P freq.
Scale 100%
(0f
max
)
(0max. speed
(02.0 x I
nCX
)
(02 x T
nCX
)
(02 x P
nCX
)
(0100% x U
nM
)
(01000 V)
(-2--+2xT
nMOT
)
(-2--+2xT
nMOT
)
(f
min
f
max
)
26
3.2
Analogue output filter
time
0.0110 s 0.01 1.00 26
3.3
Analogue output inver-
sion
011 0
0 = Not inverted
1 = Inverted
26
3.4
Analogue output mini-
mum
011 0
0 = 0 mA
1 = 4 mA
26
3.5 Analogue output scale 101000% 1% 100% 26
3.6 Digital output function 022 1 1
0 = Not used
1 = Ready
2 = Run
3 = Fault
4 = Fault inverted
5 = Vacon overheat warning
6 = External fault or warning
7 = Reference fault or warning
8 = Warning
9 = Reversed
10 = Jogging speed selected
11 = At speed
12 = Motor regulator activated
13 = Output frequency limit superv. 1
14 = Output frequency limit superv. 2
15 = Torque limit supervision
16 = Reference limit supervision
17 = External brake control
18 = Control from I/O terminals
19 = Frequency converter temperature
limit supervision
20 = Unrequested rotation direction
21 = External brake control inverted
22 = Termistor fault or warning
27
3.7 Relay output 1 function 022 1 2 As parameter 3.6
27
3.8 Relay output 2 function 022 1 3 As parameter 3.6
27
3.9
Output frequency limit 1
supervision function
021 0
0 = No
1 = Low limit
2 = High limit
27
3.10
Output frequency limit 1
supervision value
0f
max
(par. 1.2) 0.1 Hz 0 Hz 27
3.11
Output frequency limit 2
supervision function
021 0
0 = No
1 = Low limit
2 = High limit
27
3.12
Output frequency limit 2
supervision value
0f
max
(par. 1.2)
0.1 Hz 0 Hz 27
STOP
STOPSTOP
STOP
STOP
STOPSTOP
STOP
STOP
STOPSTOP
STOP
Group 3, Output and supervision parametersGroup 3, Output and supervision parameters
Group 3, Output and supervision parametersGroup 3, Output and supervision parameters
Group 3, Output and supervision parameters