acon Page 15
Multi-purpose Control Application IIMulti-purpose Control Application II
Multi-purpose Control Application IIMulti-purpose Control Application II
Multi-purpose Control Application II
Vacon Plc Phone: +358-(0)201 2121 Fax: +358-(0)201 212 205
Service: +358-40-8371 150 E-mail: vacon@vacon.com
Group 4, Drive control parametersGroup 4, Drive control parameters
Group 4, Drive control parametersGroup 4, Drive control parameters
Group 4, Drive control parameters
Code Parameter Range Step Default Custom Description Page
4
. .
. .
. 1 Acc./Dec. ramp 1 shape 010 s 0.1 s 0 0 = Linear 30
>0 = S-curve acc./dec. time
4
. .
. .
. 2 Acc./Dec. ramp 2 shape 010 s 0.1 s 0 0 = Linear 30
>0 = S-curve acc./dec. time
4
. .
. .
. 3 Acceleration time 2 0.13000 s 0.1 s 10 s 31
4
. .
. .
. 4 Deceleration time 2 0.13000 s 0.1 s 10 s 31
4
..
..
. 5 Brake chopper 01 1 0 0 = Brake chopper not in use 31
1 = Brake chopper in use
2 = External brake chopper
4
..
..
. 6 Start function 01 1 0 0 = Ramp 31
1 = Flying start
4
. .
. .
. 7 Stop function 01 1 0 0 = Coasting 31
1 = Ramp
4
. .
. .
. 8 DC-braking current 0.151.5 0.1 A 0.5 x I
nCX
31
x I
nCX
(A)
4
. .
. .
. 9 DC-braking time at Stop 0250.0 s 0.1 s 0 s 0 = DC-brake is off at Stop 32
4
. .
. .
. 10 Execute freq. of DC- 0.110 Hz 0.1 Hz 1.5 Hz 33
brake during ramp Stop
4
. .
. .
. 11 DC-brake time at Start 0.025.0 s 0.1 s 0 s 0 = DC-brake is off at Start 33
4
..
..
. 12 Multi-step speed f
min
f
max
0.1 Hz 10 Hz 33
reference 1 (1
..
..
. 1) (1
..
..
. 2)
4
..
..
. 13 Multi-step speed f
min
f
max
0.1 Hz 15 Hz 33
reference 2 (1
..
..
. 1) (1
..
..
. 2)
4
..
..
. 14 Multi-step speed f
min
f
max
0.1 Hz 20 Hz 33
reference 3 (1
..
..
. 1) (1
..
..
. 2)
4
..
..
. 15 Multi-step speed f
min
f
max
0.1 Hz 25 Hz 33
reference 4 (1
..
..
. 1) (1
..
..
. 2)
4
..
..
. 16 Multi-step speed f
min
f
max
0.1 Hz 30 Hz 33
reference 5 (1
..
..
. 1) (1
..
..
. 2)
4
..
..
. 17 Multi-step speed f
min
f
max
0.1 Hz 40 Hz 33
reference 6 (1
..
..
. 1) (1
..
..
. 2)
4
..
..
. 18 Multi-step speed f
min
f
max
0.1 Hz 50 Hz 33
reference 7 (1
..
..
. 1) (1
..
..
. 2)
Note!Note!
Note!Note!
Note! = Parameter value can be changed only when the frequency converter is stopped.
STOP
STOPSTOP
STOP
STOP
STOPSTOP
STOP

Other manuals for Vacon CX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vacon CX and is the answer not in the manual?

Vacon CX Specifications

General IconGeneral
BrandVacon
ModelCX
CategoryMedia Converter
LanguageEnglish

Related product manuals