Vacon Plc Phone: +358-(0)201 2121 Fax: +358-(0)201 212 205
Service: +358-40-8371 150 E-mail: vacon@vacon.com
Page 32
VV
VV
V
aconacon
aconacon
acon
Multi-purpose Control Application IIMulti-purpose Control Application II
Multi-purpose Control Application IIMulti-purpose Control Application II
Multi-purpose Control Application II
3.21 I/O-expander board (opt.) analogue output content3.21 I/O-expander board (opt.) analogue output content
3.21 I/O-expander board (opt.) analogue output content3.21 I/O-expander board (opt.) analogue output content
3.21 I/O-expander board (opt.) analogue output content
0 = Not used Scale 100%
1 = O/P frequency (0—f
max
)
2 = Motor speed (0—max. speed)
3 = O/P current (0—2.0 x I
nCX
)
4 = Motor torque (0—2 x T
nCX
)
5 = Motor power (0—2 x P
nCX
)
6 = Motor voltage (0—100% x U
nM
)
7 = DC-link volt. (0—1000 V)
8 = Input signal U
in
9 = Input signal I
in
10 = Refer. freq.
11 = Refer. torque
12 = Motor±torque (-2—+2xT
nMOT
)
13 = Motor±power (-2—+2xT
nMOT
)
14 = O/P freq. (f
min
—f
max
)
3.22 I/O-expander board (opt.) analogue output filter time3.22 I/O-expander board (opt.) analogue output filter time
3.22 I/O-expander board (opt.) analogue output filter time3.22 I/O-expander board (opt.) analogue output filter time
3.22 I/O-expander board (opt.) analogue output filter time
Range is 0.01 - 10 s
Step: 0.01
Default: 1.00
3.23 I/O-expander board (opt.) analogue output inversion3.23 I/O-expander board (opt.) analogue output inversion
3.23 I/O-expander board (opt.) analogue output inversion3.23 I/O-expander board (opt.) analogue output inversion
3.23 I/O-expander board (opt.) analogue output inversion
0 = No inverted
1 = Inverted
Default: 0 = no inverted
3.24 I/O-expander board (opt.) analogue output minimum3.24 I/O-expander board (opt.) analogue output minimum
3.24 I/O-expander board (opt.) analogue output minimum3.24 I/O-expander board (opt.) analogue output minimum
3.24 I/O-expander board (opt.) analogue output minimum
0 = 0 mA
1 = 4 mA
Default: 0 = 0 mA
3.25 I/O-expander board (opt.) analogue output scale3.25 I/O-expander board (opt.) analogue output scale
3.25 I/O-expander board (opt.) analogue output scale3.25 I/O-expander board (opt.) analogue output scale
3.25 I/O-expander board (opt.) analogue output scale
Range is 10% - 1000%
Step: 1%
Default: 100%