I/ O-expander board installation (Vacon CXS-range)
Vacon Plc Tel: +3 58 -2 01 2 1 2 1 Fax: + 3 5 8-2 01 2 1 2 20 5
Service: +3 5 8 -4 0 -8 37 1 1 50 E-mail: vacon@vacon.com
http:/ / w ww.vacon.com
Terminal Signal Description
206 +2 4 V C ontrol voltage output Voltage for sw itches, etc. max. 50 mA
207 GN D I/ O ground G round for reference and controls
208 CMC Common for DIC1 -DIC5 Connect to G N D or + 2 4 V
209 DIC1 External fault Contact open = no fault
(closing contact) Contact closed = fault
210 DIC2 Run disable Cont. open = start of motor enabled
Cont. closed= start of motor disabled
211 DIC3 Acceler. / Decel. time Contact open = time 1 selected
selection Contact closed = time 2 selected
212 DIC4 Jogging speed selection Contact open = no action
Contact closed = jogging speed
213 DIC5 Fault reset Contact open = no action
Contact closed = fault reset
2 1 4 N .C. N ot connected
2 15 N .C. N ot connected
221 TI+ Thermistor input
2 2 2 T I +
2 2 5 RO 4 / 1 Relay output 4 RUN
2 2 6 RO 4 / 2
4.2 Vacon CX101OPT
Signal from
motor thermistors * )
*) N OTE! Thermistor input (terminals 2 2 1 and 2 2 2 ) must be shorted if not used.
Figure 4 -2 Control connections of Vacon CX1 0 1 O PT.