EasyManua.ls Logo

Vacon optbj - Safety-Related Data According to the Standard

Vacon optbj
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
STO and SS1 safety functions vacon • 27
Local contacts: https://www.danfoss.com/en/contact-us/contacts-list/
5
5.3.7 Safety-related data according to the standard
* The values in the table above are worst case values and they are fulfilled with all board revisions.
If more detailed information is needed, contact Danfoss local contacts (http://drives.danfoss.com/
danfoss-drives/local-contacts/) for support and details.
Table 8. Safe Torque Off (STO) safety-related data *
MR4 - MR10 MR12
EN 61800-5-2:2007
SIL 3
PFH = 4.12
x10
-10
/hour
HFT = 1
SIL 3
PFH = 4.30
x10
-10
/hour
HFT = 1
EN 62061:2005
SIL CL 3
PFH = 4.12
x10
-10
/hour
HFT = 1
SIL CL 3
PFH = 4.30
x10
-10
/hour
HFT = 1
EN/ISO 13849-1:2006
PL e
MTTF
d
=1700 years
DC
avg
= medium
Category 3
PL e
MTTF
d
=700 years
DC
avg
= medium
Category 3
IEC 61508:2010,
High Demand Mode
SIL 3
PFH = 4.12
x10
-10
/hour
HFT = 1
SIL 3
PFH = 4.30
x10
-10
/hour
HFT = 1
IEC 61508:2010,
Low Demand Mode
SIL 3
PFD
AVG
(T
M
)= 3.59x10
-5
T
M
= 20 years
HFT = 1
SIL 3
PFD
AVG
(T
M
)= 3.76x10
-5
T
M
= 20 years
HFT = 1