7
vacon • 40 Maintenance
Local contacts: https://www.danfoss.com/en/contact-us/contacts-list/
30 Safety configuration 507
The hardware does not support
the OPTBJ board.
Restart the drive.
Should the fault re-occur, con-
tact the distributor near to you.
30 Safety diagnostics 520
There is a diagnostic failure in
the STO safety function. This
fault occurs when the STO
inputs are in a different state for
more than 500 ms.
Restart the drive.
If the restart does not help,
check the wiring: Both STO
input channels of OPTBJ need
to be on the same state, i.e.
safety device controlling the
inputs needs to feed or cut
power from both STO1
and STO2
channels simultaneously.
If the inputs are on the same
state and the fault re-occurs,
replace the OPTBJ board.
Should the fault re-occur, con-
tact the distributor near to you.
Deliver the fault report to the
distributor, see fault details for
more information.
30 Safety diagnostics 521
Atex-thermistor diagnostic
fault.
Restart the drive.
If the restart does not help,
change the OPTBJ board.
Should the fault re-occur, con-
tact the distributor near to you
30 Safety diagnostics 522 Atex-thermistor short-circuit.
Check the connection of the
Atex-thermistor
Check the thermistor
Restart the drive.
If the restart does not help,
change the OPTBJ board.
Should the fault re-occur, con-
tact the distributor near to you
30 Safety diagnostics 523
Problem occured in internal
safety circuit
Reset the drive and restart. If
the fault reoccurs contact your
nearest distributor.
30 Safety diagnostics 524
Overvoltage detected in safety
option board
Reset the drive and restart. If
the fault reoccurs contact your
nearest distributor.
30 Safety diagnostics 525
Undervoltage detected in safety
option board
Reset the drive and restart. If
the fault reoccurs contact your
nearest distributor.
30 Safety diagnostics 526
Internal failure detected in
safety option board CPU or
memory handling
Reset the drive and restart. If
the fault reoccurs contact your
nearest distributor.
30 Safety diagnostics 527
Internal failure detected in
safety function
Reset the drive and restart. If
the fault reoccurs contact your
nearest distributor.
Fault code Fault ID Explanation Correcting measures