10 • vacon Configuration of the AC drive
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
PDO8_Active_Fault_Code Output INT
Latest activated fault code that is not
Supported AC drives: VACON
®
100 family.
3 Configuration of the AC drive
The chapters 2.1 and 2.2 describe how to get the AC drive to communicate and to be
controllable over EtherNet/IP. One or several of the following tools can be used for
commissioning depending on the used AC drive:
• Keypad
• NCDrive (VACON
®
NXP)
• VACON
®
Live (VACON
®
100)
• NCIPConfig (OPTE9/A in all drives)
The following chapters describe the parameterization of VACON
®
100 INDUSTRIAL and
VACON
®
NXP Multi-Purpose applications. If you are using a different application, refer to the
relevant application manual for details on parameters.
3.1 EtherNet/IP parameterization
Use the OPTE9/A option board or the inbuilt EtherNet/IP of VACON
®
100.
For the OPTE9/A option board, change the following settings. These parameters can be found
under path 7.5 in VACON
®
NXP, and under path 5.4.3 in VACON
®
100 (when the OPTE9/A
option board is installed into slot E).
Table 6. OPTE9/A Ethernet parameters
For the inbuilt EtherNet/IP of VACON
®
100, change the following settings:
Table 7. VACON
®
100 Ethernet parameters (without OPTE9/A)
5.9.1.4.1 IP Address e.g. 192.168.1.10
5.9.4.1.1
EtherNet/IP Protocol in
Yes