0020244998_04 ecoTEC plus Installation and maintenance instructions 27
8 Operation
8.1 Operating concept
The operating concept and the read-off and setting facilities
of the operator level are described in the operating instruc-
tions.
An overview of the reading and setting options for the in-
staller level is included in the table in the appendix.
Installer level Overview ( Page 49)
8.2 Calling up the installer level
1. Only call up the installer level if you are a competent
person.
2. Navigate to Menu Installer level and confirm by
pressing .
3. Set the value 17 (code) and confirm by pressing .
8.3 Live Monitor (status codes)
Menu Live monitor
Status codes in the display provide information on the pro-
duct's current operating mode.
Status codes Overview ( Page 56)
8.4 Setting the hot water temperature
Danger!
Risk of death from legionella.
Legionella multiply at temperatures below
60 °C.
Ensure that the end user is familiar with
all of the Anti-legionella measures in order
to comply with the applicable regulations
regarding legionella prevention.
Set the hot water temperature.
Condition: Water hardness: > 3.57 mol/m³
Water temperature: 50