0020244998_04 ecoTEC plus Installation and maintenance instructions 49
# Maintenance work Interval
32 Opening the service valves Annually
33 Filling the heating installation at regular intervals
31
34 Starting a test operation after maintenance work Annually
35 Completing inspection and maintenance work Annually
40
36 Perform the gas family check at regular intervals
37 Visually check the ignition and burner behaviour Annually
38 Checking the CO/CO content following maintenance work Annually
39 Check the product for gas, flue gas, water and condensate leaks Annually
B Installer level Overview
Setting level Values
Unit Increment, select, explanation
Factory
setting
Min. Max.
Installer level
Enter code 00 99 1 (competent person code 17)
Installer level Fault list
F.XX F.XX¹ Current value
Installer level Test programs
Gas family check Current value LPG, natural gas
Installer level Test programs Check programs
P.00 Purging Yes, No
P.01 Maximum load Yes, No
P.02 Minimum load Yes, No
P.06 Filling mode Yes, No
Installer level Test programs Function menu
T.01 Internal pump On, Off
T.02 3-way valve On, Off
T.03 Fan On, Off
T.04 Cylinder charging pump On, Off
T.05 Circulation pump On, Off
T.06 External pump On, Off
T.08 Burner On, Off
Installer level Test programs Electronics self-test
Self-test Yes, No
Installer level Appliance config.
Language Languages available for selection Country-
specific
Target flow temp. 30 75 1
DHW temperature 30 60 1
Product with domestic hot water generation or
connected domestic hot water cylinder
Comfort mode
On, Off Off
¹Fault lists are only displayed, and can only be deleted, if faults have occurred.