50 Installation and maintenance instructions ecoTEC plus 0020244998_04
Setting level Values
Unit Increment, select, explanation
Factory
setting
Min. Max.
Auxiliary relay 1 10 1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extraction hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = eBUS remote control (not active)
9 = Anti-legionella pump (not active)
10 = Solar valve (not active)
2
Accessory relay 1 1 10 1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extraction hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = eBUS remote control (not active)
9 = Anti-legionella pump (not active)
10 = Solar valve (not active)
2
Accessory relay 2 1 10 1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extraction hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = eBUS remote control (not active)
9 = Anti-legionella pump (not active)
10 = Solar valve (not active)
2
Heating partial load kW Partial load only, full load only, auto Auto
Contact details Phone
num-
ber
0 9
Factory setting On, Off
Installer level Diagnostics menu
D.XXX D.XXX Current value
Installer level Start inst. assistant
Language Languages available for selection Country-
specific
Filling mode: 3-way valve is in mid-
position
0 2 0 = Normal operating mode
1 = Mid-position (parallel operation)
2 = Permanent heating position
Purge program: Select circ. using
+/-
Automatic adaptive purging of the heating circuit
and domestic hot water circuit
Not active
Active
Target flow temp. 30 75 1
DHW temperature 35 60 1
Product with domestic hot water generation
Comfort mode
On, Off
Heating partial load kW Partial load only, full load only, auto Auto
¹Fault lists are only displayed, and can only be deleted, if faults have occurred.