Appendix
12 Operating instructions ecoTEC plus 0020220342_01
Appendix
A Operator level overview
Setting level Values Unit Increment, select Default
setting
Min. Max.
Water pressure
Water pressure Current value bar
Live monitor
Status Current value
Information
Contact details Phone number
Serial number Permanent value
Display contrast Current value 1 25
15 40
Basic settings
Language Current language Deutsch, English, French, Italian, Danish,
Dutch, Spanish, Turkish, Hungarian, Russian,
Ukrainian, Swedish, Norwegian, Czech, Polish,
Slovakian, Romanian, Slovenian, Portugese,
Serbian, Srpski, Greek
English
Resets
Reset anti-cycl. time Current value min
B Status codes Overview
Status codes that are not listed here can be viewed in the installation instructions.
Status code Meaning
Displays in heating mode
S.00 Heating: No heat demand
S.02 Heating mode: Pump pre-run
S.03 Heating mode: Ignition
S.04 Heating mode: Burner on
S.06 Heating mode: Fan overrun
S.07 Heating mode: Pump overrun
S.08 Heating, remaining anti-cycling time xx mins
Displays in hot water handling mode
S.10 Domestic hot water requirement via impeller sensor
S.14 DHW mode: Burner on
Displays in Comfort mode (product with integrated hot water generation) or in cylinder charging mode (product with hot water generation
via an external domestic hot water cylinder)
S.20 Hot water requirement
S.22 DHW mode: Pump pre-run
S.24 DHW mode: Burner on
Other displays
S.31 No heat demand: Summer mode
S.34 Heating mode: Frost protection
S.46 Comfort protection mode, flame loss at minimum load