EasyManuals Logo

Vaillant ecoTEC plus VU User Manual

Vaillant ecoTEC plus VU
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
Appendix
0020220342_01 ecoTEC plus Operating instructions 13
C Troubleshooting
Fault Cause Measure
Product does not start
up:
No hot water
Heating remains cold
The gas isolator cock installed on-site and/or the gas
isolator cock on the product is closed.
Open both gas isolator cocks.
The power supply in the building is disconnected. Check the fuse in the building. The product
switches on automatically when the power is
restored.
The product is switched off. Switch on the product ( "Switching on the
product" section).
The heating flow temperature is set too low or to the
Heating off position, and/or the hot water temperature
is set too low.
Set the heating flow temperature and hot water
temperature ( "Setting the heating flow temper-
ature" section/ "Setting the hot water temperat-
ure" section).
The system pressure is insufficient.
Low water pressure in the heating installation (fault mes-
sage: F.22).
Fill the heating installation ( "Filling the heating
installation" section).
There is air in the heating installation. Have your competent person purge the heating
installation.
After three unsuccessful attempts to ignite the flame, the
product switches to fault mode (fault message: F.28).
Press the fault clearance key for one second.
The product makes another attempt to ignite the
flame.
If you have been unable to eliminate the ignition
fault after three fault clearance attempts, consult
a competent person.
Hot water generation
functioning correctly;
heating does not start
up.
The external controller is not set correctly. Set the external controller correctly ( Controller
operating instructions).

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant ecoTEC plus VU and is the answer not in the manual?

Vaillant ecoTEC plus VU Specifications

General IconGeneral
Energy Efficiency ClassA
Fuel TypeNatural Gas
MountingWall-mounted
ErP RatingA
DHW Heat ExchangerStainless Steel
Warranty5 years
Efficiency94%
Dimensions720 x 440 x 338 mm
Flow RateUp to 14.3 l/min
TypeWall-mounted gas condensing boiler

Related product manuals