EasyManua.ls Logo

Vaillant ecoTEC plus VUW 6/5-5 Series - C Overview of Diagnostics Codes

Vaillant ecoTEC plus VUW 6/5-5 Series
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
58 Installation and maintenance instructions 0020244997_07
Code Parameter Values or explanations
Factory
setting
Own setting
D.083 DHW burner starts Number of burner start-ups Not ad-
justable
D.084 Maintenance in Adjustment range: 0 to 3000 hrs and "---" for deactivated ā€ž---ā€
D.088 Min. DHW flow rate Switch-on delay for domestic hot water draw-off detec-
tion via impeller (only products with integrated domestic
hot water generation)
0 = 1.5 l/min and no delay,
1 = 3.7 l/min and 2 sec. delay
1.5 l/min and
no delay
D.090 eBUS controller Status of digital control
Recognised, not recognised
Not ad-
justable
D.091 Status DCF77 Status of DCF with outdoor temperature sensor connec-
ted
No reception
Reception
Synchronised
Valid
Not ad-
justable
D.092 actoSTOR communication status actoSTOR module detection
0 = Not connected
1 = Connection fault: No communication via PeBus,
actoSTOR module was previously detected
2 = Connection active
Not ad-
justable
D.093 Adjust Device Specific Number Device Specific Number (DSN)
Adjustment range: 0 to 99
D.094 Clear fault history Delete fault list
0 = No
1 = Yes
D.095 Software version: PeBUS parti-
cipant
PCB (BMU)
Display (AI)
actoSTOR (APC)
HBI/VR34
Not ad-
justable
D.096 Reset to factory settings? Reset all adjustable parameters to factory setting
0 = No
1 = Yes
D.098 Coding resistor Display xx.yy
xx = Coding resistor 1 in cable harness for output range:
8 = VU 126/5-5 (H-GB) ecoTEC plus 612; VU 156/5-5
(H-GB) ecoTEC plus 615; VU 186/5-5 (H-GB) ecoTEC
plus 618, VU 186/5-5 (P-GB) ecoTEC plus 618; VUW
196/5-5 (H-GB) ecoTEC plus 825
9 = VU 246/5-5 (H-GB) ecoTEC plus 624; VUW 246/5-5
(H-GB) ecoTEC plus 832; VUW 246/5-5 (P-GB) ecoTEC
plus 832
10 = VU 306/5-5 (H-GB) ecoTEC plus 630; VU 306/5-5
(P-GB) ecoTEC plus 630; VUW 306/5-5 (H-GB) ecoTEC
plus 835
11 = VU 386/5-5 (H-GB) ecoTEC plus 637; VUW 286/5-
5 (H-GB) ecoTEC plus 838; VUI 286/5-5 (H-GB) ecoTEC
plus 938
yy = Coding resistor 2 on PCB for gas group:
02 = P gas
03 = H gas
07 = L gas
Not ad-
justable

Table of Contents

Related product manuals