Appendix
0020250180_00 geoTHERM Installation and maintenance instructions 33
Setting level Values Unit Increment, select Default setting Setting
Min. Max.
T.147 DCF status No DCF signal
Validate DCF signal
Valid DCF signal
Installer level → Configuration →
Language Current language 01 Deutsch
02 English
03 Français
06 Nederlands
16 Norsk
18 Čeština
20 Slovenščina
27 Suomi
02 English
Contact data Phone number 0 - 9
Compressor starts at −999 0 °min 1 −60
Comp. hysteresis 3 15 K 1 7
Max. rem. feed head 200 700 mbar 1 700
Conf. heat. build. pump 1 100 % 1, auto Auto
Conf. cool. build. pump 1 100 % 1, auto Auto
Conf. DHW build. pump 1 100 % 1, auto Auto
Reset anti-cycl. time 0 120 min 1 0
Boiler supp. set p.
1)
300 1300 l/h 20 1000
Enviro. pump set p. 29 100 % 1 75
Freeze protection −14 5 ℃ 1 −7
Enable emergency mode On, Off Off
Software version Current value for the
main PCB (HMU xxxx)
and the display (AI
xxxx)
Installer level → Resets →
Switch-on delay Yes, No No
Statistics Yes, No No
Factory settings Yes, No No
Installer level → Start inst. assistant →
Language 01 Deutsch
02 English
03 Français
06 Nederlands
16 Norsk
18 Čeština
20 Slovenščina
27 Suomi
02 English
Freeze protection −13 4 ℃ 1 −7
Check programme P.05 Purge building
circuit
P.06 Purge environment
circuit
P.07 Purge environment
and building circuit
Contact data Phone number 0 - 9
1)
Can only work in conjunction with the VWZ ZK accessory.
2)
Fault lists (section 9.1) are only available, and can only be deleted, if faults have occurred.