EasyManua.ls Logo

Vaillant VEN 5 plus - Detecting and Rectifying Faults; Fault Identification and Replacement Parts

Vaillant VEN 5 plus
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating instructions for electric domestic hot water cylinders VEN 5/6 U and O (plus) 0020129648_02 21
Detecting and rectifying faults 12
12 Detecting and rectifying faults
e
Danger!
Risk of death from electric shock!
Live lines and connections may cause a
potentially lethal electric shock.
> Do not attempt to repair the unit yourself
under any circumstances.
> Do not remove the cover under any circum-
stances.
> If the unit ever malfunctions, inform an
approved heating engineer immediately.
> In the event of a fault, unplug the mains plug.
> In the event of a leak, shut off the cold water supply
to the electric domestic hot water cylinder immedi-
ately.
> Employ an approved heating engineer to rectify the
fault.
> Do not tamper with the inner workings of the unit
under any circumstances.
In the event of a fault, the safety temperature limiter
(STL) will cut out automatically.
> Always have the cause of the fault determined and
rectified by an approved heating engineer before you
attempt to restart the unit.
> If the unit has not yet been filled with water, fill the
unit first as described under section 5 "Start-up".
> To reset the STL, unplug the mains plug briefly.
Temperature controller defective
The Vaillant electric domestic hot water cylinder is
equipped with a resettable safety temperature limiter
(STL).
In the event of a temperature controller defect, the
safety temperature limiter prevents damage caused by
overheating.
If the temperature controller is defective or if the elec-
tric domestic hot water cylinder is otherwise damaged:
> Unplug the mains plug.
> Ensure that the power cannot be restored inadvert-
ently to any of the supply lines and connections.
> Open the electric domestic hot water cylinder.
> Determine and rectify the cause of the fault
> If necessary, replace the temperature controller
and/or safety temperature limiter.
> Close the casing on the electric domestic
hot water cylinder.
> Plug the mains plug back in.
12.1 Replacement parts
An overview of the available genuine Vaillant replace-
ment parts can be obtained:
from your wholesaler (replacement parts catalogue,
printed or on CD-ROM)
in the Vaillant Expert PartnerNET (replacement parts
service) at http://www.vaillant.com/.
The mains connection line must be exchanged only for
a Vaillant connection line, see applicable replacement
parts catalogue.