14 Technical data
26 Installation instructions 0020237057_01
14.2 Radio receiver unit
Rated voltage
24 V
Rated current
< 50 mA
Rated surge voltage
330 V
Frequency band
868.0
868.6 MHz
Max. transmission power
< 25 mW
Range outdoors
100 m
Range indoors
25 m
Degree of contamination
2
Level of protection
IP 20
Protection class
III
Temperature for the ball temperature test
75
Maximum permitted ambient temperature
0 60
Rel. room humidity
35 90 %
Supply line cross-section
0.75 1.5 mm²
Height
115 mm
Width
147 mm
Depth
50 mm
14.3 Outdoor temperature sensor
Power supply
Solar cell with
energy store
Reserve power supply (with full energy
store)
30 days
Rated surge voltage
330 V
Frequency band
868.0
868.6 MHz
Max. transmission power
< 25 mW
Range outdoors
100 m
Range indoors
25 m
Degree of contamination
2
Level of protection
IP 44
Protection class
III
Temperature for the ball temperature test
75
Permissible operating temperature
40 60
Height
110 mm
Width
76 mm
Depth
41 mm

Table of Contents

Other manuals for Vaillant VRC 700f/4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant VRC 700f/4 and is the answer not in the manual?

Vaillant VRC 700f/4 Specifications

General IconGeneral
BrandVaillant
ModelVRC 700f/4
CategoryHeat Pump
LanguageEnglish

Related product manuals