User’s Guide ______________________________________________________________________
72 __________________________________________________________________ M210906EN-C
The response:
a<cr><lf>
Example:
0<cr><lf>
0<cr><lf>
Wind Data Message (aR1)
With this command you can request the wind data message.
Command format: aR1<cr><lf>
Example of the response (the parameter set is configurable):
0R1,Dn=236D,Dm=283D,Dx=031D,Sn=0.0M,Sm=1.0M,
Sx=2.2M<cr><lf>
where
a = Device address
<cr><lf> = Response terminator
where
a = Device address
R1 = Wind message query command
<cr><lf> = Command terminator
where
a = Device address
R1 = Wind message query command
Dn = Wind direction minimum (D = degrees)
Dm = Wind direction average (D = degrees)
Dx = Wind direction maximum (D = degrees)
Sn = Wind speed minimum (M = m/s)
Sm = Wind speed average (M = m/s)
Sx = Wind speed maximum (M = m/s)
<cr><lf> = Response terminator