EQUIPMENT DESCRIPTION
2- Technical Data Sheet
Cooling capacity 70.000 BTU/h (20,5kW) 85.000 BTU/h (25kW) 85.000 BTU/h (25kW)
Heating Capacity (Optional) 75.000 BTU/h (22kW) 75.000 BTU/h (22kW) 75.000 BTU/h (22kW)
Type R134a R134a R134a
Quantity ( * ) 2,8 kg 2,8 kg 2,8 kg
Model of blowers Centrífugal Centrífugal Centrífugal
Quantity of blowers 4 4 4
Air flow (free blowing) 4.200 m³/h 4.200 m³/h 4.200 m³/h
Nominal current 87 A / 57 A 87 A / 57 A 87 A / 57 A
Model of blowers Axial Axial Axial
Quantity of blowers 2 2 2
Air flow (free blowing) 5.800 m
³
/h 5.800 m
³
/h 5.800 m
³
/h
Nominal current 87 A / 57 A 87 A / 57 A 87 A / 57 A
Model (alternative type) SP 22 SP 32 SP 32
Displacement 212 cm³ 313 cm³ 313 cm³
Maximum rotation allowed 4.500 RPM 4.500 RPM 4.500 RPM
Lubricating oil (PAG) 027-00001-000 (PAG) 027-00001-000 (PAG) 027-00001-000
Amount used 630 ml 660 ml 660 ml
Type Eletromagnetic Eletromagnetic Eletromagnetic
Voltage 24V 24V 24V
( * ) The quantity of refrigerant gas can vary according to the application and installation.
When you have defrost, add 1kg more in the amount of refrigerant.
CC 205 CC 205W
CLUTCH
Component
AIR CONDITIONING
CC 185
COOLING GAS
EVAPORATOR
CONDENSER
COMPRESSOR
Characteristics
CC 185T - CC 205T - CC 205W
15