19
Metal Detector VMH3CS – Operation Manual
© 2007 Vallon GmbH, D-72800 Eningen/Germany
The lighting diode on the LED-display is shifted either to the left or to the
right according to the mineral concentration of the present soil.
7. Stop pressing button „C“: You will hear one short tone (beep) which
confirms the storage of the achieved data.
3.3.3 Important Notes
NOTE
Start soil compensation only after the detector has adapted itself to the
ambient temperature. In case of more than 15°C difference in temperature
between storeroom and detection place wait for approx. 10 minutes.
NOTE
If the audio signal does not become smaller during the up-and-down-
movement of the search, please check whether a metal object has been
detected.
NOTE
When pressing, by mistake, button “C” during detection longer than approx.
3 seconds, the ground balance will change to another soil condition. You must
repeat the procedure.
NOTE
The program “mineral” adapts the detector to the metallic properties of the
soil. Mines containing metal components with the same electromagnetic
features may be overlooked.
Use program „mineral“ only if absolutely necessary.
Recommendation:
Create a test field in the soil to be detected. This field should contain all mines
to be expected.