11. FINAL REVIEW
11.1 All models except black & chrome front casting: Fit
the fire front casting to the front surround. Locate the two
screw heads at the rear top corners of the casting through
the keyhole slots at the inner sides of the surround. If the
screw heads do not project enough or project too far, the
screws can be adjusted. Lower the casting so that it rests on
the hearth (see figure 24).
Black & chrome front casting: Place the fire front casting in
front of the appliance.
11.2 Place the bottom front cover casting in position
below the fire front casting.
11.3 Visually inspect the appliance. Clean off any marks
incurred during installation.
11.4 Hand these instructions and the user's instructions
to the customer.
11.5 Advise the customer how to operate the appliance.
Point out that lighting instruction details are on a tie at the
bottom of the appliance.
11.6 Explain to the customer that the appliance has a
flame failure & spillage monitoring system. Point out the
explanation of this system shown in the owners guide
under “Operating the fire”.
Advise that if the fire goes out for any reason, wait at least
three minutes before relighting.
Stress that if the monitoring system repeatedly shuts off
the fire, the appliance should be switched off and a
specialist should be consulted.
11.7 Advise the customer that they should read their
Owners guide before operating the fire and always follow
the advice in the section headed “Cleaning your fire”.
11.8 Stress that no extra coals must be added over and above
those supplied with the appliance and that any replacements must
only be the authorised spares. Warn that ignoring this advice
could cause incomplete clearance of the products of combustion
with consequent health hazards.
11.9 Recommend that the appliance should be serviced
and the chimney inspected by a competent person at least
annually.
Fig. 24 Fire front casting location