Series 075  MAINTENANCE 
 
 
6  Maintenance 
 
 
WARNING 
Unqualified personnel 
Inappropriate handling may cause serious injury or property damage. 
Only qualified personnel are allowed to carry out the described work. 
 
 
 
WARNING 
Hazardous components 
Human body parts may get jammed and severely injured.  
Before starting maintenance: 
–  disconnect compressed air supply 
–  disconnect electrical power supply 
 
 
 
WARNING 
Movable parts 
Human body parts may get jammed and severely injured. 
Keep human body parts away from movable parts. 
 
 
6.1  Maintenance intervals 
Under clean operating conditions the product does not require any maintenance during 
specified lifetime. 
 
 
•  Influences from the process may require more frequent maintenance. 
•  If the door has reached the specified life cycle – see product data sheet – 
we recommend a general overhaul by VAT. Please contact one of our 
service centers. You will find the contact data on our website 
www.vatvalve.com. 
 
 
6.2  Required tools 
•  Allen wrench size 3, 4 and 5 
•  Torque wrench 4.5 Nm / 6 Nm / 9 Nm 
•  Cleanroom wiper soaked with alcohol (2% methyl ethyl ketone) 
•  O-Ring removal tool; see «Table 11-1» on page 28 
 
 
 
Figure 6-1