Installation, Operating &
Maintenance Instructions
601899EC
Edition
2014
-
08
-
20
Door L-VAT
with double acting pneumatic actuator
Series 075
50 × 336 mm (1.97" × 13.23")
This manual is valid for the following product ordering numbers:
075..- ....
-
....
Sample picture

Questions and Answers

  • G
    Garrett WilliamsAug 5, 2025
    Why VAT 075 Controller gate slides at chamber wall?
    • C
      Cindy GuerraAug 5, 2025
      If the VAT Controller gate slides at the chamber wall, there are several potential causes: 1. **Installation and initial command**: Follow the correct sequence: move the door to the open position, attach the door to the chamber, connect air to the “OPEN” port only, block port “P” so no air can leave, connect air tubing to the “P” port and apply CDA, and then move the door to the “CLOSED” position. 2. **Compressed air**: Verify that the compressed air pressure is within the required range of 4 – 7 bar. 3. **Air tubing**: Ensure the compressed air supply tubing has the correct length and diameter. 4. **Connection of air lines**: Check the compressed air lines for proper connection.

VAT 075 Series Specifications

General IconGeneral
BrandVAT
Model075 Series
CategoryController
LanguageEnglish