2.4 MOUNTING
WARNING: Risk of explosion! Never install the controller in a
sealed enclose with flooded batteries! Do not install in a
confined area where battery gas can accumulate.
WARNING: Risk of electric shock! When wiring the
solarmodules,the PV array can produce a high opencircuit
voltage, so turn off the breaker before wiring and be careful when
wiring.
CAUTION
The controller requires at least 150mm of
clearance above and below for proper air flow. Ventilation is
highly recommended if mounted in an enclosure.
Installation procedure:
Step 1: Determination of installation location and heat-
dissipation space
Determination of installation location: The controller shall
be installed in a place with sufficient air flow through the
radiators of the controller and a minimum clearance of
150 mm from the upper and lower edges of the controller
Figure2-1