Vector VI 200 - Communication Parameter Settings

Vector VI 200
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual
Page 17 of 27
C10 Power saving setting
[C10 0] close backlight
[C10 1] close backlight after 1 minute
[C10 2] always backlight
C11 Hold
[C11 0] No Hold function
[C11 1] Peck hold
[C11 2] Data hold
[C11 3] Auto-hold
[C11 4] Animal weighing
C12 Hold time ( if you choose C11=4, you can set the time )
[C12 3] 3 seconds
[C12 5] 5 seconds
C13 Upper limit alarm value
C14 Low limit alarm value
C15 Check inner code
4.4Communicationsetting
C18 Serial interface setting
[C18 0] No sending
[C18 1] Big display
[C18 2] Print format output
[C18 3] Command mode(Z =zero T=tare R=Reply weight
[C18 4] continuous sending
C19 BAUD RATE
[C19 0] 1200bit/s