EasyManua.ls Logo

Vector VI 200 - Maintenance and Troubleshooting; Error Codes and Solutions

Vector VI 200
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual
Page 24 of 27
6. Maintenance
6.1RegularErrorandmaintainmethod
Error Reason instruction Solution
Display
UUUUUU
1. the loaded weight
excess overload range of
max. capacity
2. wrong connection
with load cell or no
connection with it.
3. load cell unworkable
1.decrease loaded weight
2. check load cell
connection
3. checking load cellcheck
input and output resistance
to judge it is good or not.
Display nnnnnn
1. calibration is no good
2 cell single line is
connect a wrong line.
3the cell is bad.
1. check scale is resisted or
not, foot is kept level or not.
2. check load cell
connection.
3. checking load cellcheck
input and output resistance
to judge it is good or not.
ERR1
during calibration, no
input added weight or
input weight exceed
max capacity.
Input the correct weight