5.3 Hardware Sync
Manual VN5610/VN5610A Version 2.0 48
to synchronize the time stamps to a common time base (master clock) which is
defined by the application.
CANalyzer/CANoe
CAN
FlexRay
Vector
CAN Interface
CH2
Time Stamp Clock
USB
Vector
FR Interface
CHB
Master Time Stamp Clock
synchronization
by hardware (SYNCcable)
sec
0.000000
1.10037
5
1.20038
1
2.30037
1
2.40040
5
3.50059
2
3.60024
1
CH1
CHA
sec
0.000000
1.100376
1.200382
2.300372
2.400406
3.500593
3.600242
PC
USB
Figure 38: Time stamps are synchronized to the master clock
Note
The hardware synchronization must be supported by the application. For further
information please refer to the relevant application manual. Please note that the soft-
ware synchronization must be disabled (see Vector Hardware Config | General
information | Settings | Software time synchronization) if the hardware syn-
chronization is used.