Wiring/Miscellaneous For TLS-IB Consoles W/RS-232 & RS-485 TLS-IB Specifications
5-8
TLS-IB Specifications
PHYSICAL SPECIFICATIONS
Width w/door closed: 188 mm (7.6”) - Width w/door open: 235 mm (9.6”)
Height: 163 mm (6.7”)
Depth w/door closed: 50 mm (2.6”), Depth w/door open: 228 mm (9”)
Weight: 1.8 kg (3.5 lbs)
The TLS-IB unit contains one CPU/Power Supply board (in unit)
Removable plug type connections
Conduit knockouts for intrinsically-safe wiring: 1/2”, 3/4”, and 1” I.P.S. (2 places)
ENVIRONMENTAL SPECIFICATIONS
TLS-IB storage and operation: indoor, climate controlled
Operating temperature range: 0 to +40°C
Storage temperature range: -40 to +74°C
LVD and EMC compliant
UL/cUL approved and ATEX approved
ELECTRICAL SPECIFICATIONS
TLS-IB operating voltage: 120/240 Vac, 2 A max
Power Supply fuses F1 and F2 are NOT
field replaceable. The rating for both fuses is 2 A, Type T (Time Lag)
Intrinsically-safe circuit for scanning Mag Probes
SOFTWARE SPECIFICATIONS
System software upgradeable by a PC program
RAM clear jumper (Figure 5-2 on page 5-3)
Factory boot-up mode for self testing
Supports tank volume reports.
Supports Density and Density Offset
SERIAL COMMUNICATIONS INTERFACE (SCI)
RS-232 or RS-485
Baud rate options: 300, 600, 1200, 2400, 4800, 9600; default 2400
Parity options: None, Odd, Even; default Even
Data length options: 8 or 7; default 7
Number of stop bits options: 1 or 2; default 1