16
7 Supplement
VEGAFLEX 86 • Modbus and Levelmaster protocol
47614-EN-230605
7 Supplement
7.1 Technical data
Note for approved instruments
The technical data in the respective safety instructions which are included in delivery are valid for
approvedinstruments(e.g.withExapproval).Thesedatacandierfromthedatalistedherein,for
exampleregardingtheprocessconditionsorthevoltagesupply.
All approval documents can be downloaded from our homepage.
Electromechanical data - version IP67
Options of the cable entry
Ʋ Cable entry M20x1.5;½NPT
Ʋ Cable gland M20x1.5;½NPT(cableøseebelowtable)
Ʋ Blind plug M20x1.5;½NPT
Ʋ Closing cap ½NPT
Material ca-
ble gland
Material seal
insert
Cable diameter
4.5 … 8.5 mm 5 … 9 mm 6 … 12 mm 7 … 12 mm 10 … 14 mm
PA NBR – ● ● – ●
Brass,nickel-
plated
NBR
● ● ● – –
Stainless
steel
NBR
– ● ● – ●
Wire cross-section (spring-loaded terminals)
Ʋ Massivewire,strandedwire 0.2 … 2.5 mm² (AWG 24 … 14)
Ʋ Stranded wire with end sleeve 0.2 … 1.5 mm² (AWG 24 … 16)
Voltage supply
Operating voltage 8 … 30 V DC
Max.powerconsumption 520 mW
Reverse voltage protection Integrated